BAUDOUIN APD275BD Diesel Generator – 50Hz
The Aksa APD275BD Diesel Generator is a 275 kVA standby / 250 kVA prime power generator powered by a Baudouin 6M16G6D0/S diesel engine. Designed for reliable 400/230V, 50Hz three-phase power, it features electronic governing, brushless alternator technology, DSE 7320 AMF control, and robust construction for commercial and industrial standby power applications.
Brand: BAUDOUIN
Aksa APD275BD Diesel Generator ? 275 kVA Standby Power
The Aksa APD275BD Diesel Generator is a diesel generating set designed for dependable standby and prime power applications. Powered by a Baudouin 6M16G6D0/S diesel engine, this generator provides stable 400/230V, 50Hz three-phase power for commercial, industrial, and infrastructure environments.
With a standby rating of 275 kVA / 220 kW and a prime rating of 250 kVA / 200 kW, the APD275BD is suitable for sites requiring reliable high-capacity backup or prime power.
Key Features
- 275 kVA standby power and 250 kVA prime power
- Powered by a Baudouin 6M16G6D0/S diesel engine
- Turbocharged and aftercooled engine design
- 6-cylinder inline engine configuration
- Electronic governor system for stable performance
- Brushless, single-bearing alternator
- Class H insulation system
- Self-excited and self-regulating alternator
- Solid state Automatic Voltage Regulator
- Deep Sea Electronics DSE 7320 AMF control module
- Integrated fuel tank with 470 litre capacity
- Available in open type or sound attenuated canopy configuration
Engine Specifications
| Engine Brand | Baudouin |
|---|---|
| Engine Model | 6M16G6D0/S |
| Engine Power Output | 264 kWm / 353.8 HP |
| Engine Speed | 1500 rpm |
| Aspiration & Cooling | Turbocharged and aftercooled |
| Total Displacement | 9.726 litres |
| Cylinders | 6-cylinder, inline |
| Bore x Stroke | 126 x 130 mm |
| Compression Ratio | 17:1 |
| Governor | Electronic |
| Fuel Consumption at Full Load | 56.9 L/hr |
| Fuel Tank Capacity | 470 litres |
| Oil Capacity | 30 litres |
| Coolant Capacity | 42 litres |
| Radiator Cooling Air | 415 m?/min |
| Air Intake | 18 m?/min |
| Exhaust Gas Flow | 50.6 m?/min |
Power Ratings
| Standby Power | 275 kVA / 220 kW |
|---|---|
| Prime Power | 250 kVA / 200 kW |
| Voltage | 400/230 V |
| Frequency | 50 Hz |
| Phase | 3 Phase |
| Power Factor | 0.8 |
Alternator Features
- Brushless, single-bearing alternator design
- Revolving field construction
- Flexible disc rotor system
- 4-pole construction
- Class H insulation system
- Self-excited and self-regulating system
- Solid state Automatic Voltage Regulator
- 2/3 pitch stator winding for improved harmonics
- Direct drive centrifugal blower fan cooling
- Standard degree of protection IP22
- IP23 protection available as an option
- No-load waveform total harmonic distortion below 1.5%
- Balanced linear load waveform distortion below 5%
- Telephone Influence Factor below 50 per NEMA MG1-22.43
- Telephone Harmonic Factor below 2%
Control System
The APD275BD is equipped with an Auto Mains Failure control panel featuring the DSE 7320 control module. This system monitors the mains supply and generator output, automatically starting and stopping the generating set when required.
- Microprocessor-based AMF control module
- Automatic control of mains and generator contactors
- Engine performance monitoring
- AC power output monitoring
- LED alarm indication
- Front panel configuration of timers and alarm trip points
- Easy push button control
- Static battery charger
- Emergency stop push button
- Power outlet terminal board mounted on the genset base frame
Monitoring Functions
- Generator voltage monitoring, L-L and L-N
- Generator current monitoring for L1, L2 and L3
- Generator frequency monitoring
- Generator kVA and kWh monitoring
- Generator kW as percentage of rated kW setting
- Generator power factor monitoring
- Engine oil pressure monitoring
- Engine temperature monitoring
- Plant battery voltage monitoring
- Engine running hours display
- Mains voltage monitoring, phase-to-phase and phase-to-neutral
Protection Features
- Over speed and under speed protection
- Low and high battery voltage alarm
- Start and stop failure protection
- Charge failure alarm
- Over current protection
- Under/over generator voltage protection
- Low oil pressure alarm
- Emergency stop protection
- High engine temperature alarm
- kW overload protection
- Unbalanced load protection
- Independent earth fault trip
Dimensions and Weight
| Open Type Dimensions | 2795 x 1300 x 1753 mm |
|---|---|
| Open Type Dry Weight | 2200 kg |
| Sound Attenuated Type Dimensions | 3933 x 1356 x 2176 mm |
| Sound Attenuated Type Dry Weight | 3000 kg |
Standard Specifications
- Heavy-duty Baudouin diesel engine
- Four-stroke, water-cooled engine
- Turbocharged and aftercooled design
- Direct injection fuel system
- Electronic governor system
- 24V DC starter and charge alternator
- Replaceable fuel filter, oil filter and dry element air filter
- Cooling radiator and fan
- Starter battery with rack and cables
- Flexible fuel connection hoses
- Manual oil sump drain valve
- Industrial capacity exhaust silencer and steel bellows
- Jacket water heater for automatic models
- Operation manuals and circuit diagram documents
Applications
The Aksa APD275BD is suitable for commercial buildings, industrial facilities, factories, warehouses, telecom sites, healthcare facilities, construction sites, and emergency backup power systems where reliable diesel standby or prime power is required.
Optional Equipment
- Oil heater
- 3/4 pole output circuit breaker
- Anti-condensation heater
- Bulk fuel tank
- Automatic filling system
- Fuel-water separator filter
- Low fuel level alarm
- Residential silencer
- Enclosure or sound proof canopy
- Trailer option
- Manual oil drain pump
- Maintenance tool kit
- Charge ammeter
- 3-pole or 4-pole transfer switch
- Earth fault protection
The Aksa APD275BD Diesel Generator is built for dependable medium-capacity power generation, combining Baudouin diesel engine technology, DSE 7320 AMF control, brushless alternator performance, and durable construction for demanding standby and prime power applications.
| Standby KVA | 0-20 KVA |
|---|






