HYUNDAI AD750 Diesel Generator – 50Hz

The Aksa AD750 Diesel Generator is a 750 kVA standby / 680 kVA prime power generator powered by a heavy-duty Hyundai DP222LB diesel engine. Designed for reliable 50Hz three-phase power, it features electronic governing, brushless alternator technology, DSE 7320 AMF control, and robust industrial construction for commercial and industrial standby power applications.

Brand: HYUNDAI

Aksa AD750 Diesel Generator ? 750 kVA Standby Power

The Aksa AD750 Diesel Generator is a high-capacity diesel generating set designed for dependable standby and prime power applications. Powered by a heavy-duty Hyundai DP222LB diesel engine, this generator delivers reliable performance, efficient operation, and stable power output for demanding industrial, commercial, and infrastructure environments.

With a standby rating of 750 kVA / 600 kW and a prime rating of 680 kVA / 544 kW, the AD750 is suitable for sites requiring stable 400/230V, 50Hz three-phase power.

Key Features

  • 750 kVA standby power and 680 kVA prime power
  • Powered by a Hyundai DP222LB diesel engine
  • Turbocharged and intercooled engine design
  • 12-cylinder V-type diesel engine
  • Electronic governor system for stable performance
  • Brushless, single-bearing alternator
  • Class H insulation system
  • Self-excited and self-regulating alternator
  • Solid state Automatic Voltage Regulator
  • Deep Sea Electronics DSE 7320 AMF control module
  • Integrated fuel tank with 1000 litre capacity
  • Available in open type or sound attenuated canopy configuration

Engine Specifications

Engine BrandHyundai
Engine ModelDP222LB
Engine Power Output664 kWm / 890 HP
Engine Speed1500 rpm
Aspiration & CoolingTurbocharged intercooled
Total Displacement21.927 litres
Cylinders12-cylinder, V-type
Bore x Stroke128 x 142 mm
Compression Ratio15:1
GovernorElectronic control
Fuel Consumption at Full Load147.1 L/hr
Fuel Tank CapacityOpen: 1000 litres / Canopy: 1000 litres
Oil Capacity40 litres
Coolant Capacity114 litres
Radiator Cooling Air860 m?/min
Air Intake42.5 m?/min
Exhaust Gas Flow120 m?/min

Power Ratings

Standby Power750 kVA / 600 kW
Prime Power680 kVA / 544 kW
Voltage400/230 V
Frequency50 Hz
Power Factor0.8

Alternator Features

  • Brushless, single-bearing alternator design
  • Revolving field construction
  • Flexible disc rotor system
  • 4-pole construction
  • Class H insulation
  • Self-excited and self-regulating system
  • Solid state Automatic Voltage Regulator
  • 2/3 pitch stator winding for improved harmonics
  • Direct drive centrifugal blower fan cooling
  • Standard degree of protection IP21
  • No-load waveform total harmonic distortion below 1.5%
  • Balanced linear load waveform distortion below 5%

Control System

The AD750 is equipped with an Auto Mains Failure control panel featuring the DSE 7320 control module. This system monitors the mains supply and generator performance, automatically starting and stopping the generating set when required.

  • Microprocessor-based AMF control module
  • Automatic control of mains and generator contactors
  • Engine performance monitoring
  • AC power output monitoring
  • LED alarm indication
  • Front panel configuration of timers and alarm trip points
  • Easy push button control
  • Static battery charger
  • Emergency stop push button

Monitoring Functions

  • Generator voltage monitoring, L-L and L-N
  • Generator current monitoring for L1, L2 and L3
  • Generator frequency monitoring
  • Engine oil pressure monitoring
  • Engine temperature monitoring
  • Plant battery voltage monitoring
  • Engine running hours display
  • Mains voltage monitoring
  • Generator kVA and kWh monitoring
  • Generator kW percentage monitoring
  • Generator power factor monitoring

Protection Features

  • Over speed and under speed protection
  • Low and high battery voltage alarm
  • Start and stop failure protection
  • Charge failure alarm
  • Over current protection
  • Under/over generator voltage protection
  • Low oil pressure alarm
  • Emergency stop protection
  • High engine temperature alarm
  • kW overload protection
  • Unbalanced load protection
  • Independent earth fault trip

Dimensions and Weight

Open Type Dimensions3470 x 1550 x 2303 mm
Open Type Dry Weight4200 kg
Sound Attenuated Type Dimensions5313 x 1606 x 2658 mm
Sound Attenuated Type Dry Weight5500 kg

Standard Specifications

  • Heavy-duty Hyundai diesel engine
  • Four-stroke, water-cooled engine
  • Direct injection fuel system
  • 12/24V DC starter and charge alternator
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Starter battery with rack and cables
  • Flexible fuel connection hoses
  • Manual oil sump drain valve
  • Industrial capacity exhaust silencer and steel bellows
  • Jacket water heater for automatic models
  • Operation manuals and circuit diagram documents

Applications

The Aksa AD750 is suitable for industrial facilities, commercial buildings, data centres, hospitals, manufacturing plants, telecom infrastructure, construction sites, and emergency backup systems where dependable high-output diesel power is required.

Optional Equipment

  • Oil heater
  • 3/4 pole output circuit breaker
  • Anti-condensation heater
  • Bulk fuel tank
  • Automatic fuel filling system
  • Fuel-water separator filter
  • Low fuel level alarm
  • Residential silencer
  • Enclosure or sound proof canopy
  • Trailer option
  • Manual oil drain pump
  • Maintenance tool kit

The Aksa AD750 Diesel Generator is built for dependable high-output power generation, combining Hyundai diesel engine technology, DSE 7320 control, brushless alternator performance, and durable industrial construction for demanding standby and prime power requirements.

Standby KVA

401-999 KVA

Share This Product: