CUMMINS AC1675 Diesel Generator – 50Hz
AKSA AC1675 diesel generator set rated at 1675 kVA / 1340 kW standby and 1500 kVA / 1200 kW prime power. Powered by a Cummins KTA50GS8 diesel engine, this 400/230V, 50Hz, 3-phase generator is built for heavy-duty standby, prime, industrial, and commercial power applications, with electronic governor control, brushless alternator, and DSE 7320 AMF control panel.
Brand: CUMMINS
Product Overview
The AKSA AC1675 is a high-capacity diesel generating set designed for reliable standby and prime power applications. It delivers 1675 kVA / 1340 kW standby power and 1500 kVA / 1200 kW prime power at 400/230V, 50Hz, 3-phase output with 0.8 power factor.
Powered by a Cummins KTA50GS8 diesel engine, the AC1675 uses a 16-cylinder V-type, 50.3-litre, turbocharged and aftercooled engine running at 1500rpm. The engine features direct fuel injection, electronic governor control, water cooling, and heavy-duty diesel performance for demanding commercial and industrial environments.
The generator set includes a brushless, single-bearing alternator with Class H insulation, self-excited regulation, 2/3 pitch stator winding, and low harmonic distortion. The DSE 7320 control panel provides automatic mains failure operation, generator monitoring, alarm protection, LED indication, and push-button control for safe and practical operation.
Key features
- 1675 kVA / 1340 kW standby power
- 1500 kVA / 1200 kW prime power
- Cummins KTA50GS8 diesel engine
- 16-cylinder V-type engine configuration
- 50.3-litre displacement
- Turbocharged and aftercooled engine
- 400/230V, 50Hz, 3-phase output
- 1500rpm engine speed
- 0.8 power factor
- Electronic governor system
- Direct injection fuel system
- Water-cooled diesel engine
- Brushless single-bearing alternator
- Class H alternator insulation
- Self-excited and self-regulating alternator
- 2/3 pitch stator winding for improved harmonics
- DSE 7320 automatic mains failure control panel
- Static battery charger and emergency stop push button
- Suitable for standby, prime, commercial, and industrial power use
Technical summary
| Manufacturer | AKSA Power Generation |
| Model | AC1675 |
| Fuel type | Diesel |
| Standby power | 1675 kVA / 1340 kW |
| Prime power | 1500 kVA / 1200 kW |
| Voltage | 400/230V |
| Frequency | 50Hz |
| Phase | 3 Phase |
| Power factor | 0.8 |
| Engine | Cummins KTA50GS8 |
| Engine power output | 1429 kWm / 1915 HP |
| Engine speed | 1500rpm |
| Cylinders | 16 cylinders, V-type |
| Displacement | 50.3 litres |
| Bore x stroke | 159 x 159 mm |
| Compression ratio | 14.9:1 |
| Aspiration | Turbocharged and aftercooled |
| Cooling | Water cooled |
| Governor | Electronic |
| Fuel consumption at full load | 309 L/hr |
| Oil capacity | 204 litres |
| Coolant capacity | 345 litres |
| Radiator cooling air | 1302 m?/min |
| Air intake | 94.86 m?/min |
| Exhaust gas flow | 242 m?/min |
| Alternator design | Brushless, single bearing, revolving field |
| Stator | 2/3 pitch |
| Rotor | Single bearing, flexible disc |
| Insulation class | Class H |
| Exciter type | Self excited |
| Alternator cooling | Direct drive centrifugal blower fan |
| Total harmonic distortion | No load < 1.5%; balanced linear load < 5% |
| Control panel | DSE 7320 |
| Open type dimensions | 5570 x 2100 x 2538 mm |
| Open type dry weight | 10670 kg |
Control system
The AC1675 is equipped with a DSE 7320 automatic mains failure control panel mounted on the generator base frame. The module monitors mains supply, starts and stops the generator set, controls mains and generator contactors, monitors engine performance, and provides AC power output supervision.
- Automatic mains failure control
- Microprocessor-based control module
- Static battery charger
- Emergency stop push button
- Generator voltage, current, frequency, kVA, kW, kWh, and power factor monitoring
- Engine oil pressure, engine temperature, battery voltage, and engine hours monitoring
- LED alarm indication
- Front panel configuration of timers and alarm trip points
- Push-button controls for stop/reset, manual, test, auto, mute alarm, and start
Protection and alarms
- Over speed and under speed protection
- Low and high battery voltage alarm
- Start and stop failure alarm
- Charge fail alarm
- Over current protection
- Under and over generator voltage protection
- Low oil pressure protection
- Emergency stop alarm
- High engine temperature protection
- kW overload protection
- Unbalanced load alarm
- Independent earth fault trip
Standard equipment
- Heavy-duty Cummins diesel engine
- Cooling radiator and fan
- Starter battery with rack and cables
- Flexible fuel connection hoses
- Manual oil sump drain valve
- Industrial exhaust silencer and steel bellows
- Jacket water heater on automatic models
- Brushless alternator with AVR
- Anti-vibration mounting
- Operation manuals and circuit diagram documents
Optional equipment
- Oil heater
- 3-pole or 4-pole output circuit breaker
- Alternator anti-condensation heater
- Bulk fuel tank
- Automatic fuel filling system
- Fuel-water separator filter
- Low fuel level alarm
- Residential silencer
- Soundproof canopy or enclosure
- Trailer
- Manual oil drain pump
- Maintenance tool kit
| Standby KVA | 1000 KVA and Over |
|---|